  • Insulated Multi-Strand
    Annealed Copper Conductor
    House Wires
  • Insulated Annealed Copper
    Conductor Single Core Wires
  • PVC Insulated & Sheathed
    Annealed Copper Conductor
    Multi Core Cables
  • Submersible Flat Cables
  • Welding Cables


Application

These multi core flexible cables are used for wiring in control panels, machines and various electrical installations in dry and damp interiors especially under typical industrial environmental conditions.

Features

Manufactured from bright-annealed 99.97% pure bare copper conductors these cables offer low conductor resistance. These wires are insulated with a special grade PVC compound formulated and manufactured in-house. The tough robust outer PVC jacket protects it from the oils, greases, various chemicals and abrasions giving long life and electrical safety.

Technical Specification

PVC Insulated & sheathed annealed copper conductor multi core cables

Size in sq. mm. Size in mm. Current Rating Approximate overall diameter of cable in mm
2 core 3 core 4 core
0.50 16/0.20 4 6.20 6.60 7.20
0.75 24/0.20 7 6.80 7.20 7.90
1.00 32/0.20 11 7.00 7.50 8.10
1.50 48/0.20 / 30/0.25 14 7.60 8.10 9.00
2.50 80/0.20 / 50/0.25 19 9.00 9.60 10.50
4.00 56/0.30 26 10.60 11.30 12.40
6.00 84/0.30 33 12.60 13.40 15.20
10.00 140/0.30 / 80/0.40 45 16.00 17.00 18.80
16.00 226/0.30 / 126/0.40 60 18.80 20.10 22.20
25.00 354/0.30 / 196/0.40 75 24.00 25.60 28.20
35.00 276/0.40 102 - 27.50 30.50
50.00 396/0.40 138 - 31.70 35.60

* Note insulation thickness, Sheath thickness and overall dimensions given in this table are nominal value. The strand diameter is nominal. However, Construction of the Conductor is designed to satisfy the requirement of conductor resistence as per IS8130 : 1984

PVC Insulated & sheathed annealed copper conductor flexible control cables confirming to IS : 694

Size in
sq. mm.
Size in mm. Current Rating Approximate overall diameter of cable in mm
5 core 6 core 7 core 8 core 10 core 12 core 14 core 16 core 19 core 24 core
0.50 16/0.20 4 8.30 8.50 8.50 9.30 10.80 11.20 12.00 12.60 13.20 15.60
0.75 24/0.20 7 9.10 9.50 9.50 10.40 12.20 12.60 13.30 14.20 14.90 17.60
1.00 32/0.20 11 9.60 9.80 9.80 10.70 12.60 13.00 13.70 14.60 15.60 18.20
1.50 48/0.20 / 30/0.25 14 10.30 10.70 10.70 11.90 13.80 14.30 15.20 16.00 17.10 20.20
2.50 80/0.20 / 50/0.25 19 11.70 12.70 12.70 14.10 16.60 17.20 18.10 19.30 20.30 23.80
4.00 56/0.30 26 13.95 15.30 15.30 16.90 20.00 20.70 21.80 23.20 24.50 28.80

* Note insulation thickness, Sheath thickness and overall dimensions given in this table are nominal value. The strand diameter is nominal. However, Construction of the Conductor is designed to satisfy the requirement of conductor resistence as per IS8130 : 1984